Performance And Test Conditions
●Standard Test Conditions
test and measurement shall be done under temperature of 25±5℃ and relative humidity of 45~48%.

●Measuring Instrument or Apparatus
①Dimension Measuring Instrument
The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.1mm.
②Voltmeter
Standard class specified in the national standard or more sensitive class having inner impedance more than 10kΩ/V.
③Ammeter
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω.
④Impedance Meter
Impedance shall be measured by a sinusoidal alternating current method (1kHz LCR meter)

●Standard Charge/Discharge
①Standard charge:Test procedure and its criteria are referred as follows:
0.2 C=Charging shall consist of charging at a 0.2 C constant current rate until the cell reaches 4.2V. The cell shall then be charged at constant voltage 0f 4.2v when the charging current has tapered to 0.02 C. Charge time:Approx 6.0h,
②Standard Discharge
0.2C=Cells shall be discharged at a constant current of 0.2C to 2.0 volts @25℃±5℃.
③If no otherwise specified, the rest time between Charge and Discharge amount to 10min.

●Appearance
There shall be no such defect as flaw, crack, rust, leakage, which may adversely affect commercial value of battery.
 
Warning
● Prohibition short circuit

●Notice for Designing Battery Pack
Pack toughness
Battery pack should have sufficient strength and the Li-ion cell inside should be protected from mechanical shocks.
Cell fixing
The Li-ion cell should be fixed to the battery pack by its large surface area.
No cell movement in the battery pack should be allowed.
Tab connection
Spot welding is recommended for Li-Fe tab connection method.
Battery pack should be designed that shear force are not applied to the Li-Fe tabs.

●Prohibition of disassembly
1)Never disassemble the cells
The disassembling may generate internal short circuit in the cell, which may cause gassing, firing, explosion, or other problems.
2) Electrolyte is harmful
Li-Fe battery should not have liquid from electrolyte flowing, but in case the electrolyte come into contact with the skin, or eyes, physicians shall slush the electrolyte immediately with fresh water and medical advice is to be sought.

●Prohibition of dumping of cells into fire
Never incinerate nor dispose the cells in fire. These may cause explosion of the cells, which is very dangerous and is prohibition.

●Battery cells replacement
The battery replacement shall be done only by either cells supplier or device supplier and never be done by the user.

●Prohibition of use of damaged cells
The cells might be damaged during shipping by shock. If any abnormal features of the cells are found such as damages in a plastic envelop of the cell, deformation of the cell package, smelling of an electrolyte an electrolyte leakage and others, the cells shall never be used any more.
The cells with a smell of the electrolyte or a leakage shall be placed away from fire to avoid firing or explosion.

●Period of Warranty
The period of warranty is a year from the date of shipment. Brillipower guarantees to give a replacement in case of cells with defects proven due to manufacturing process instead of the customer abuse and misuse.

●Storing the Batteries
The batteries should be stored at room temperature, charged to about 30% to 50% of capacity.
We recommend that batteries be charged about once per half a year to or event over discharge.

●Other The Chemical Reaction
Because batteries utilize a chemical reaction, battery performance over time even if stored for a long period of time without being used. In addition, if the various usage conditions such as charge, ambient temperature, etc. are not maintained within the specified ranges the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage. if the batteries cannot maintain a charge for long periods of time, even when they are charged correctly, this may idicate it is time to change the battery.



                                                            
Share:

Tel: 86-0755-28767566

Fax: 86-0755-28767566

Address: 6F Jingkai Building,Silicon Valley Power Qinghu Park,Longhua New District,Shenzhen,China
Scans the two-dimensional code direct access.
Copyright ©2005 - 2015 Brillipower Co. Ltd. Guangdong ICP 09063742 -1